Facebook
Twitter
YouTube
Menu
Home
Start here
About Us
Eye-Catching
Products
Unique
Services
Default contents
Featured Products
Compatible with other extensions
Parts and Accessories
Equity Rental Programs
Affordable solution
Sell Us Your Equipment
Contact
Siemens Servo 300A Ventilator
Quick Overview
Siemens Servo 300A Ventilator
Details
Basic Description Manufacturer: MAQUET GmbH & Co. KG Ventilator Type: Positive Pressure Invasive Conventional High Frequency Ventilator Class: Intensive Care Unit (ICU) Patient Population Range: Neonatal Pediatric Adult Description Features: Automode feature enhances the process of weaning Brief Description: Go Beyond The Static Specs! Click Here For Special Online Interactive Content! (Requires Flash Player 5.0) Characteristics Modes--Invasive: Volume-controlled modes --- SIMV, SIMV + Pressure Support Pressure-controlled modes --- SIMV, SIMV + Pressure Support Combined modes --- Automatic mode switch between Pressure Control and Pressure Support; Volume Control and Volume Support; Pressure Regulated Volume Control and Volume Support Operating Range of Controls: CMV frequency: 5 - 150 breaths/min; SMV frequency: 0.5 - 40 breaths/min; Inspiration time: 10% - 80% of breath cycle time (stepless); Pause time: 0% - 30% of breath cycle time (stepless); Pressure control: 0 - 100 cm H2O; Pressure support: 0 - 100 cm H2O; PEEP: 0 - 50 cm H2O; Trigger sensitivity: Flow: 3 - 32 ml/s (green marked area); Pressure: -17 - 0 cm H2O; Trigger bias flow: Neonate: 8 ml/s (0.5 l/min); Pediatric: 16 ml/s (1 l/min); Adult: 32 ml/s (2 l/min); Inspiration rise time: 0% - 10% of breath cycle time (stepless); Preset Tidal Volume: 2 - 4000 ml; Preset Minute Volume: 0.2 - 60 l/min; Oxygen breaths: 100% for 20 breaths or max 1 min; Oxygen concentration: 21% to 100% Triggering: Flow, pressure Size: Patient Unit: 242mm W x 370mm D x 240mm H; Control Unit: 431mm W x 150mm D x 325mm H Weight: approximately 24 kg Other Characteristics: The switch from controlled to supported mode is caused by patient triggering efforts; The switch from supported to controlled mode happens after 12 seconds apnea (Adult), 5 seconds apnea (Pediatric), or 5 seconds apnea (Neonate) Other monitored variables; Inspiratory period (I:E ratio): set; O2 ratio: set, measured: Gas supply pressure: measured (air and O2); Battery voltage: measured (internal and external) Characteristics (Non - Technical) Approvals: Class 1 equipment Type B according to IEC 601-1/EN 60 601-1 Specifications Front Panel Controls: CMV frequency; SMV frequency; Inspiration time; Pause time; Pressure control; Pressure support; PEEP; Trigger sensitivity; Trigger bias flow; Inspiration rise time; Preset Tidal Volume; Preset Minute Volume; Oxygen breaths; Start breath: Initiation of 1 breath in all modes; Pause hold: Inspiration or expiration; Patient range: Neonate/Pediatric/Adult; Oxygen concentration: Automode: On/Off Power Requirements: Inlet gas pressure: 2 - 6.5 bar (29 - 94 PSI), air and O2; Power supply: 100, 120, 220, and 240 VAC +/- 10%; 50 - 60 Hz; Battery: Back-up time: Approximately 30 minutes; Recharge time: Approximately 10 hours; External battery input 24 V DC; Power consumption: 50 W (stand alone) Alarms: Alarm silence; Alarm reset Alarm Controls: Airway pressure (upper): 15 - 120 cm H2O; O2 concentration (high and low): set value +/- 6%; Expired minute volume: Upper alarm limit: Adult/pediatric: 0 - 60 l/min; Neonate: 0 - 6 l/min; Lower alarm limit: Adult/pediatric: 0.3 - 40 l/min; Neonate: 0.06 - 4 l/min Non-Adjustable Alarms: High continuous pressure: Apnea: Neonate: 10 seconds; Pediatric: 15 seconds; Adult: 20 seconds; Gas supply; Battery; Technical Interface Ports: Serial port: RS232 communication; Analog terminal: For analog outputs; Master/slave connection: For ILV (Independent Lung Ventilation) synchornization; Auxiliary equipment: for optional equipment Other Specifications: Flow range: 0.1 ml/s - 3 l/s; Operating Conditions: Temperature range: +15°C to +35°C (60°F to 90°F); Relative humidity: 30% to 50%; Atmospheric pressure: 700 to 1060 hPa (525 to 705mm Hg); Non-Operating Conditions: Impact: In accordance with IEC 68-2-29Eb; Peak acceleration: 15 g; Pulse duration: 6 ms; Number of impacts: 1000; Storage temperature range: -25°C to +70°C (-13°F to 158°F) Monitored Variables : Pressure Peak, Mean, Pause, End expiratory, Airway Respiratory Rate Set, Measured Tidal Volume Set, Inspiratory, Expiratory Minute Volume Expiratory
Go to top